10 - 20KA Double phase surge protection device for installation in distribution boards 

Place of Origin: Guangdong, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: AIA-1

10-20KA surge protector double phase surge protection device for  for installation in distribution boar

10-20KA surge protector double phase surge protection device for  for installation in distribution boards

 

 

Product Description

 

Surge Protection for Solar Photovoltaic (PV) System
The OBV6 series Surge Protection are designed to protect against lightning surge voltages in photovoltaic power supply networks. These units must be installed in parallel on the DC networks to be protected and provide common and differential modes protection. The OBV6-B+C40 series is available for the main operating voltages in photovoltaic: 1000 Vdc.
 
The use of OBV6-B+C40 series Surge Protection is recommended at both ends of the DC power supply line (solar panel side and inverter/converter side), especially if the line routing is external and long. The electrical diagram of the OBV6-B+C40 series is based on high energy MOVs equipped with specific thermal disconnectors and related failure indicators. The OBV6B+C40 series is made with plug-in modules to allow a fast and easy maintenance in case of failure (disconnection from the DC network).
 
em DC SURGE PROTECTIVE DEVICE
Code FSP-D40
Pole 2P 3P
Voltage 500VDC,600VDC 800VDC,900VDC,1000VDC
In(8/20)us(KA) 20KA
Imax(8/20)us(KA) 40KA
Standard IEC/EN61643
Type II
Characteristic Curve B,C,D
Working Temperature “-5°”to +40°
Protection Degree IP20
Electrical life  More than 8000times
Mechanical life More than 2000times
Dimension(W)X(H)X(D) 36x90x68 54x90x68
Installation 35MM DIN RAIL
Accessory Remote signal
Installation Altitude ≤2000M

 

 

 

Installation instructions

 

1. You must cut off the power supply before installation, live line work is strictly prohibited.

2. In protecting front line fuse or automatic circuit breaker. 

3. Protector for the parallel installation, Kevin connection is recommended (for Kevin wiring convenience, operates two terminals on the module, which is a straight up. Kevin v-like connection is a connection. A contact point and the two lines in parallel, one into, a calculated). Connector requires solid and reliable, and short, thick and straight. 

4. When installed according to the installation diagram shows the connection, where l (L1, L2, L3) for the line, n is neutral, PE ground wire, do not mistake. After the installation is complete, check that the protection unit is plug in place, close the automatic circuit breaker (fuse) switch, check the working status is normal.

5. Protector in use during the fault display window should periodically verify and view state when red fault display window or remote Terminal outputs alarm signals, the protector fails, should be repaired or replaced in a timely manner. 

 

bigPhoto
 Mr. John

Tel: 86-577-62053322
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

ZHEJIANG SINGI ELECTRICAL LLC [China (Mainland)]


Business Type:Manufacturer
City: Wenzhou
Province/State: Zhejiang
Country/Region: China (Mainland)

You May Like:

Product (196)